York
Parameters
- Climatic class:
III (ambient temp. of +25oC, relative humidity of 60%) - Temperature range:
+2 ÷ +8oC - For external condensing unit
York
Type | Length without sides* [mm] | Depth [mm] | Height [mm] | Useful surface [m2] |
---|---|---|---|---|
100 | 1000 | 70 (680) / 80 (775) / 90 (875) 110 (1075) |
2000±30 (YR) / 2250±30 (YR PL) |
2,3 (2,8) / 2,7 (3,2) / 3,4 (3,9) / 3,8 (4,3) |
125 | 1250 | 2,9 (3,5) / 3,4 (4,0) / 4,3 (4,9) / 4,75 (5,36) | ||
150 | 1500 | 3,5 (4,2) / 4,1 (4,8) / 5,1 (5,8) / 5,7 (6,45) | ||
187 | 1875 | 4,3 (5,2) / 5,1 (6,0) / 6,4 (7,3) / 7,13 (8,1) | ||
200 | 2000 | 4,6 (5,6) / 5,4 (6,4) / 6,8 (7,8) / 7,6 (8,6) | ||
250 | 2500 | 5,8 (7,0) / 6,8 (8,0) / 8,6 (9,8) / 9,5 (10,7) | ||
300 | 3000 | 6,9 (8,4) / 8,1 (9,6) / 10,2 (11,7) / 11,4 (12,9) | ||
375 | 3750 | 8,7 (10,5) / 10,2 (12,0) / 12,9 (14,7) / 14,25 (16,1) |
THE MANUFACTURER RESERVES THE RIGHT TO CHANGE THE TECHNICAL PARAMETERS OF THE APPLIANCE
For information about the energy class of the device, please contact us. Depending on the configuration, this class may change. The correct energy efficiency class is presented on the label added to the configured device.
- Construction of power coated steel
- Double glass sides or solid sides made of powder coated steel exterior and mirror steel interior
- Top lighting LED
- 5 (PR)/ 6 (PR PL) rows of adjustable shelves
- Night blind
- Forced cooling
- Automatic defrosting
- Expansion valve
- For external condensing unit (AZ): Cooling power demand: for 70, 80, 90/H2000 open version "O" - 1400W/rm and H225 – 1550W/rm at evaporating temp. -10°C and condensation temp. of +45°
- For external condensing unit (AZ): Cooling power demand: for 110/H2000 open version "O" - 1500W/rm and H225 open version "O"– 1650W/rm at evaporating temp. -10°C and condensation temp. of +45°
- For external condensing unit (AZ): Cooling power demand: for 70, 80, 90, 110/H2000 and H225 closed version "Z" – 900W/rm at evaporating temp. -10°C and condensation temp. of +45°
- Construction of stainless steel
- Highlighted shelves LED
- Strips with hooks
- Plexiglas or wired stoppers
- Stainless steel interior and angled roof F&V version
- Evaporator with heater
- Multiplexing
- Vertical lighting LED
- Vertical plexiglas or double mirror side insulated divider
- Glass sliding doors (DP) - cooling power demand 900W/rm at evaporating temp. -10°C and condensation temp. of +45°C
- Glass hinged doors (DU) - cooling power demand 900W/rm at evaporating temp. -10°C and condensation temp. of +45°C
- Possibility of using energy-saving evaporator fans
- Electromagnetic valve